Skip to content
VulniPulse
Highest advisory severityHigh 1 vendor · 1 advisory

CVE-2026-16313

CVE-2026-16313: 1 tracked advisory record across Red Hat. Compare source-reported impact, fixes and remediation.

Compare the source-linked records below. Ratings and product/version details belong to each advisory; they are not a single CVE-wide score or proof that every listed product is affected. How VulniPulse collects and checks evidence.

Vendor advisory comparison

Red Hat

1 advisory
  • Advisory severityHigh7.6

    High [CVE-2026-16313] arbitrary command execution via udev property injection in sg_inq --export

    CVE-2026-16313Source published Source updated

    A flaw was found in sg3_utils. The sg_inq command, when invoked with the --export option, outputs device identification data without sanitizing control characters in SCSI name string fields. A newline character embedded in a device-supplied name string can inject arbitrary properties into the udev device database. This could allow an attacker who can present a crafted SCSI device to execute arbitrary commands as root when the device is disconnected. sg3_utils versions 1.34 through 1.48 contain a command injection flaw in the export_dev_ids() function of sg_inq. A crafted SCSI/USB device can embed a newline in this field, splitting sg_inq's udev KEY=VALUE output into two lines and injecting an arbitrary udev property, including REMOVE_CMD. On systems whose default udev rules invoke sg_inq…

    Affected products in this advisory
    • Red Hat Enterprise Linux 10
    • Red Hat Enterprise Linux 8.4 Advanced Mission Critical Update Support
    • Red Hat Enterprise Linux 8.4 Extended Update Support Long-Life Add-On
    • Red Hat Enterprise Linux 8.6 Advanced Mission Critical Update Support

    9 more entries in the full advisory.

    Source-reported affected versions
    Affected-version details not available in this record.
    Source-reported fixed versions
    • sg3_utils-0:1.48-7.el10_2.1
    • sg3_utils-0:1.44-6.el8_10.1
    • sg3_utils-0:1.44-5.el8_4.1
    • sg3_utils-0:1.44-5.el8_6.1

    16 more entries in the full advisory.

    Mitigation guidance
    • Remove or comment out the REMOVE_CMD rule from 50-udev-default.rules to prevent command execution on device removal. Alternatively, if automatic SCSI device identification is not required, disable the udev rule that invokes sg_inq --export on device connection.

Android app · Google Play

Monitor future Red Hat CVEs from your phone.

Choose a whole vendor or a precise platform, then receive matching security advisories by phone notification, email, or both. Coverage follows 32 official vendor sources and 160+ reviewed platform categories.

Matching phone alertsOptional email delivery