24 advisories tracked · Juniper SIRT (JSA) via NVD · checked automatically every minute
Pick your product and enter the exact software release it runs. We match it against the affected/fixed versions in Juniper's recent advisories.
Juniper SIRT (JSA) via NVD
Juniper's advisory portal (kb.juniper.net) is a login-walled Salesforce app, so VulniPulse ingests Juniper SIRT (JSA) advisories from NVD, filtered to Juniper's own CNA (sirt@juniper.net) — official, machine-readable data with the affected Junos releases in each description. Junos on SRX/MX/EX/QFX and Junos Space are the common targets.
Visit Juniper Networks security advisoriesAn OS Command Injection vulnerability in the CLI processing of Juniper Networks Junos OS and Junos OS Evolved allows a local, high-privileged attacker executing specific, crafted CLI commands to inject arbitrary shell commands as root, leading to a complete compromise of the system. Certain 'set system' commands, when executed with crafted arguments, are not properly sanitized, allowing for arbitrary shell injection. These shell commands are executed as root, potentially allowing for complete control of the vulnerable system. This issue affects: Junos OS: * all versions before 22.4R3-S8, * from 23.2 before 23.2R2-S5, * from 23.4 before 23.4R2-S7, * from 24.2 before 24.2R2-S2, * from 24.4 before 24.4R2, * from 25.2 before 25.2R2; Junos OS Evolved: * all versions before 22.4R3-S8-EVO, * from 23.2 before 23.2R2-S5-EVO, * from 23.4 before 23.4R2-S7-EVO, * from 24.2 before 24.2R2-S2-EVO, * from 24.4 before 24.4R2-EVO, * from 25.2 before 25.2R1-S1-EVO, 25.2R2-EVO.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the chassis control daemon (chassisd) of Juniper Networks Junos OS on SRX1500, SRX4100, SRX4200 and SRX4600 allows a local attacker with low privileges to cause a complete Denial of Service (DoS). When a specific 'show chassis' CLI command is executed, chassisd crashes and restarts which causes a momentary impact to all traffic until all modules are online again. This issue affects Junos OS on SRX1500, SRX4100, SRX4200 and SRX4600: * 23.2 versions before 23.2R2-S6, * 23.4 versions before 23.4R2-S7 * 24.2 versions before 24.2R2-S2, * 24.4 versions before 24.4R2, * 25.2 versions before 25.2R1-S1, 25.2R2.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the chassis control daemon (chassisd) of Juniper Networks Junos OS on SRX1600, SRX2300 and SRX4300 allows a local attacker with low privileges to cause a complete Denial of Service (DoS). When a specific 'show chassis' CLI command is executed, chassisd crashes and restarts which causes a momentary impact to all traffic until all modules are online again. This issue affects Junos OS on SRX1600, SRX2300 and SRX4300: * 24.4 versions before 24.4R1-S3, 24.4R2. This issue does not affect Junos OS versions before 24.4R1.
A Missing Release of Memory after Effective Lifetime vulnerability in the DHCP daemon (jdhcpd) of Juniper Networks Junos OS on MX Series, allows an adjacent, unauthenticated attacker to cause a memory leak, that will eventually cause a complete Denial-of-Service (DoS). In a DHCPv6 over PPPoE, or DHCPv6 over VLAN with Active lease query or Bulk lease query scenario, every subscriber logout will leak a small amount of memory. When all available memory has been exhausted, jdhcpd will crash and restart which causes a complete service impact until the process has recovered. The memory usage of jdhcpd can be monitored with: user@host> show system processes extensive | match jdhcpd This issue affects Junos OS: * all versions before 22.4R3-S1, * 23.2 versions before 23.2R2, * 23.4 versions before 23.4R2.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the packet forwarding engine (pfe) of Juniper Networks Junos OS on specific EX and QFX Series devices allow an unauthenticated, adjacent attacker to cause a complete Denial of Service (DoS). On EX4k, and QFX5k platforms configured as service-provider edge devices, if L2PT is enabled on the UNI and VSTP is enabled on NNI in VXLAN scenarios, receiving VSTP BPDUs on UNI leads to packet buffer allocation failures, resulting in the device to not pass traffic anymore until it is manually recovered with a restart.This issue affects Junos OS: * 24.4 releases before 24.4R2, * 25.2 releases before 25.2R1-S1, 25.2R2. This issue does not affect Junos OS releases before 24.4R1.
A Missing Release of Memory after Effective Lifetime vulnerability in the Layer 2 Address Learning Daemon (l2ald) of Juniper Networks Junos OS and Junos OS Evolved allows an adjacent, unauthenticated attacker to cause a memory leak ultimately leading to a Denial of Service (DoS). In an EVPN-MPLS scenario, routes learned from remote multi-homed Provider Edge (PE) devices are programmed as ESI routes. Due to a logic issue in the l2ald memory management, memory allocated for these routes is not released when there is churn for these routes. As a result, memory leaks in the l2ald process which will ultimately lead to a crash and restart of l2ald. Use the following command to monitor the memory consumption by l2ald: user@device> show system process extensive | match "PID|l2ald" This issue affects: Junos OS: * all versions before 22.4R3-S5, * 23.2 versions before 23.2R2-S3, * 23.4 versions before 23.4R2-S4, * 24.2 versions before 24.2R2; Junos OS Evolved: * all versions before 22.4R3-S5-EVO, * 23.2 versions before 23.2R2-S3-EVO, * 23.4 versions before 23.4R2-S4-EVO, * 24.2 versions before 24.2R2-EVO.
A Missing Authorization vulnerability in the CLI of Juniper Networks Junos OS and Junos OS Evolved allows a local user with low privileges to read sensitive information. A local user with low privileges can execute the CLI command 'show mgd' with specific arguments which will expose sensitive information. This issue affects Junos OS: * all versions before 22.4R3-S8, * 23.2 versions before 23.2R2-S6, * 23.4 versions before 23.4R2-S6, * 24.2 versions before 24.2R2-S4, * 24.4 versions before 24.4R2-S1, * 25.2 version before 25.2R1-S2, 25.2R2; Junos OS Evolved: * all versions before 23.2R2-S6-EVO, * 23.4 version before 23.4R2-S6-EVO, * 24.2 version before 24.2R2-S4-EVO, * 24.4 versions before 24.4R2-S1-EVO, * 25.2 versions before 25.2R2-EVO.
A Missing Release of Memory after Effective Lifetime vulnerability in the BroadBand Edge subscriber management daemon (bbe-smgd) of Juniper Networks Junos OS on MX Series allows an adjacent, unauthenticated attacker to cause a Denial of Service (DoS). If the authentication packet-type option is configured and a received packet does not match that packet type, the memory leak occurs. When all memory available to bbe-smgd has been consumed, no new subscribers will be able to login. The memory utilization of bbe-smgd can be monitored with the following show command: user@host> show system processes extensive | match bbe-smgd The below log message can be observed when this limit has been reached: bbesmgd[<PID>]: %DAEMON-3-SMD_DPROF_RSMON_ERROR: Resource unavailability, Reason: Daemon Heap Memory exhaustion This issue affects Junos OS on MX Series: * all versions before 22.4R3-S8, * 23.2 versions before 23.2R2-S5, * 23.4 versions before 23.4R2-S6, * 24.2 versions before 24.2R2-S2, * 24.4 versions before 24.4R2, * 25.2 versions before 25.2R2.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the packet forwarding engine (pfe) of Juniper Networks Junos OS on MX Series allows an unauthenticated, network-based attacker to bypass the configured firewall filter and access the control-plane of the device. On MX platforms with MPC10, MPC11, LC4800 or LC9600 line cards, and MX304, firewall filters applied on a loopback interface lo0.n (where n is a non-0 number) don't get executed when lo0.n is in the global VRF / default routing-instance. An affected configuration would be: user@host# show configuration interfaces lo0 | display set set interfaces lo0 unit 1 family inet filter input <filter-name> where a firewall filter is applied to a non-0 loopback interface, but that loopback interface is not referred to in any routing-instance (RI) configuration, which implies that it's used in the default RI. The issue can be observed with the CLI command: user@device> show firewall counter filter <filter_name> not showing any matches. This issue affects Junos OS on MX Series: * all versions before 23.2R2-S6, * 23.4 versions before 23.4R2-S7, * 24.2 versions before 24.2R2, * 24.4 versions before 24.4R2.
An Incorrect Initialization of Resource vulnerability in the packet forwarding engine (pfe) of Juniper Networks Junos OS on specific EX Series and QFX Series device allows an unauthenticated, network-based attacker to cause an integrity impact to downstream networks. When the same family inet or inet6 filter is applied on an IRB interface and on a physical interface as egress filter on EX4100, EX4400, EX4650 and QFX5120 devices, only one of the two filters will be applied, which can lead to traffic being sent out one of these interfaces which should have been blocked. This issue affects Junos OS on EX Series and QFX Series: * 23.4 version 23.4R2-S6, * 24.2 version 24.2R2-S3. No other Junos OS versions are affected.
An Incorrect Synchronization vulnerability in the management daemon (mgd) of Juniper Networks Junos OS and Junos OS Evolved allows a network-based attacker with low privileges to cause a complete Denial-of-Service (DoS) of the management plane. When NETCONF sessions are quickly established and disconnected, a locking issue causes mgd processes to hang in an unusable state. When the maximum number of mgd processes has been reached, no new logins are possible. This leads to the inability to manage the device and requires a power-cycle to recover. This issue can be monitored by checking for mgd processes in lockf state in the output of 'show system processes extensive': user@host> show system processes extensive | match mgd <pid> root 20 0 501M 4640K lockf 1 0:01 0.00% mgd If the system still can be accessed (either via the CLI or as root, which might still be possible as last resort as this won't invoke mgd), mgd processes in this state can be killed with 'request system process terminate <PID>' from the CLI or with 'kill -9 <PID>' from the shell. This issue affects: Junos OS: * 23.4 versions before 23.4R2-S4, * 24.2 versions before 24.2R2-S1, * 24.4 versions before 24.4R1-S3, 24.4R2; This issue does not affect Junos OS versions before 23.4R1; Junos OS Evolved: * 23.4 versions before 23.4R2-S5-EVO, * 24.2 versions before 24.2R2-S1-EVO, * 24.4 versions before 24.4R1-S3-EVO, 24.4R2-EVO. This issue does not affect Junos OS Evolved versions before 23.4R1-EVO;
A Permissive List of Allowed Input vulnerability in the CLI of Juniper Networks Support Insights (JSI) Virtual Lightweight Collector (vLWC) allows a local, high privileged attacker to escalate their privileges to root. The CLI menu accepts input without carefully validating it, which allows for shell command injection. These shell commands are executed with root permissions and can be used to gain complete control of the system. This issue affects all JSI vLWC versions before 3.0.94.
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Juniper Networks Junos Space allows an attacker to inject script tags in the list filter field that, when visited by another user, enables the attacker to execute commands with the target's permissions, including an administrator. This issue affects all versions of Junos Space before 24.1R5 Patch V3.
A Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in the advanced forwarding toolkit (evo-aftmand/evo-pfemand) of Juniper Networks Junos OS Evolved on PTX Series or QFX5000 Series allows an unauthenticated, adjacent attacker to cause a Denial of Service (DoS).An attacker sending crafted multicast packets will cause line cards running evo-aftmand/evo-pfemand to crash and restart or non-line card devices to crash and restart. Continued receipt and processing of these packets will sustain the Denial of Service (DoS) condition. This issue affects Junos OS Evolved PTX Series: * All versions before 22.4R3-S8-EVO, * from 23.2 before 23.2R2-S5-EVO, * from 23.4 before 23.4R2-EVO, * from 24.2 before 24.2R2-EVO, * from 24.4 before 24.4R2-EVO. This issue affects Junos OS Evolved on QFX5000 Series: * 22.2-EVO version before 22.2R3-S7-EVO, * 22.4-EVO version before 22.4R3-S7-EVO, * 23.2-EVO versions before 23.2R2-S4-EVO, * 23.4-EVO versions before 23.4R2-S5-EVO, * 24.2-EVO versions before 24.2R2-S1-EVO, * 24.4-EVO versions before 24.4R1-S3-EVO, 24.4R2-EVO. This issue does not affect Junos OS Evolved on QFX5000 Series versions before: 21.2R2-S1-EVO, 21.2R3-EVO, 21.3R2-EVO, 21.4R1-EVO, and 22.1R1-EVO.
A Missing Authentication for Critical Function vulnerability in command processing of Juniper Networks Junos OS allows a privileged local attacker to gain access to Linux-based line cards as root. This issue affects systems running Junos OS using Linux-based line cards. Affected line cards include: * MPC7, MPC8, MPC9, MPC10, MPC11 * LC2101, LC2103 * LC480, LC4800, LC9600 * MX304 (built-in FPC) * MX-SPC3 * SRX5K-SPC3 * EX9200-40XS * FPC3-PTX-U2, FPC3-PTX-U3 * FPC3-SFF-PTX * LC1101, LC1102, LC1104, LC1105 This issue affects Junos OS: * all versions before 22.4R3-S8, * from 23.2 before 23.2R2-S6, * from 23.4 before 23.4R2-S6, * from 24.2 before 24.2R2-S3, * from 24.4 before 24.4R2, * from 25.2 before 25.2R2.
A Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability in the method to collect FPC Ethernet firmware statistics of Juniper Networks Junos OS on MX10k Series allows a local, low-privileged attacker executing the 'show system firmware' CLI command to cause an LC480 or LC2101 line card to reset. On MX10k Series systems with LC480 or LC2101 line cards, repeated execution of the 'show system firmware' CLI command can cause the line card to crash and restart. Additionally, some time after the line card crashes, chassisd may also crash and restart, generating a core dump.This issue affects Junos OS on MX10k Series: * all versions before 21.2R3-S10, * from 21.4 before 21.4R3-S9, * from 22.2 before 22.2R3-S7, * from 22.4 before 22.4R3-S6, * from 23.2 before 23.2R2-S2, * from 23.4 before 23.4R2-S3, * from 24.2 before 24.2R2.
An Incorrect Calculation vulnerability in the Layer 2 Control Protocol Daemon (l2cpd) of Juniper Networks Junos OS Evolved allows an unauthenticated network-adjacent attacker flapping the management interface to cause the learning of new MACs over label-switched interfaces (LSI) to stop while generating a flood of logs, resulting in high CPU usage. When the issue is seen, the following log message will be generated: op:1 flag:0x6 mac:xx:xx:xx:xx:xx:xx bd:2 ifl:13302 reason:0(REASON_NONE) i-op:6(INTRNL_OP_HW_FORCE_DELETE) status:10 lstatus:10 err:26(GETIFBD_VALIDATE_FAILED) err-reason 4(IFBD_VALIDATE_FAIL_EPOCH_MISMATCH) hw_wr:0x4 ctxsync:0 fwdsync:0 rtt-id:51 p_ifl:0 fwd_nh:0 svlbnh:0 event:- smask:0x100000000 dmask:0x0 mplsmask 0x1 act:0x5800 extf:0x0 pfe-id 0 hw-notif-ifl 13302 programmed-ifl 4294967295 pseudo-vtep underlay-ifl-idx 0 stack:GET_MAC, ALLOCATE_MAC, GET_IFL, GET_IFF, GET_IFBD, STOP, This issue affects Junos OS Evolved: * all versions before 21.4R3-S7-EVO, * from 22.2 before 22.2R3-S4-EVO, * from 22.3 before 22.3R3-S3-EVO, * from 22.4 before 22.4R3-S2-EVO, * from 23.2 before 23.2R2-S1-EVO, * from 23.4 before 23.4R1-S2-EVO, 23.4R2-EVO.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the packet forwarding engine (PFE) of Juniper Networks Junos OS on EX4k Series and QFX5k Series platforms allows an unauthenticated network-adjacent attacker flapping an interface to cause traffic between VXLAN Network Identifiers (VNIs) to drop, leading to a Denial of Service (DoS). On all EX4k and QFX5k platforms, a link flap in an EVPN-VXLAN configuration Link Aggregation Group (LAG) results in Inter-VNI traffic dropping when there are multiple load-balanced next-hop routes for the same destination. This issue is only applicable to systems that support EVPN-VXLAN Virtual Port-Link Aggregation Groups (VPLAG), such as the QFX5110, QFX5120, QFX5200, EX4100, EX4300, EX4400, and EX4650. Service can only be restored by restarting the affected FPC via the 'request chassis fpc restart slot <slot-number>' command. This issue affects Junos OS on EX4k and QFX5k Series: * all versions before 21.4R3-S12, * all versions of 22.2 * from 22.4 before 22.4R3-S8, * from 23.2 before 23.2R2-S5, * from 23.4 before 23.4R2-S5, * from 24.2 before 24.2R2-S3, * from 24.4 before 24.4R2.
A Missing Release of Memory after Effective Lifetime vulnerability in the routing protocol daemon (rpd) Juniper Networks Junos OS and Junos OS Evolved allows an unauthenticated attacker controlling an adjacent IS-IS neighbor to send a specific update packet causing a memory leak. Continued receipt and processing of these packets will exhaust all available memory, crashing rpd and creating a Denial of Service (DoS) condition. Memory usage can be monitored through the use of the 'show task memory detail' command. For example: user@junos> show task memory detail | match ted-infra TED-INFRA-COOKIE 25 1072 28 1184 229 user@junos> show task memory detail | match ted-infra TED-INFRA-COOKIE 31 1360 34 1472 307 This issue affects: Junos OS: * from 23.2 before 23.2R2, * from 23.4 before 23.4R1-S2, 23.4R2, * from 24.1 before 24.1R2; Junos OS Evolved: * from 23.2 before 23.2R2-EVO, * from 23.4 before 23.4R1-S2-EVO, 23.4R2-EVO, * from 24.1 before 24.1R2-EVO. This issue does not affect Junos OS versions before 23.2R1 or Junos OS Evolved versions before 23.2R1-EVO.
An Improper Handling of Exceptional Conditions vulnerability in packet processing of Juniper Networks Junos OS allows an unauthenticated, network-adjacent attacker sending a specifically malformed ICMP packet to cause an FPC to crash and restart, resulting in a Denial of Service (DoS). When an ICMP packet is received with a specifically malformed IP header value, the FPC receiving the packet crashes and restarts. Due to the specific type of malformed packet, adjacent upstream routers would not forward the packet, limiting the attack surface to adjacent networks. This issue only affects ICMPv4. ICMPv6 is not vulnerable to this issue. This issue does not affect AFT-based line cards such as the MPC10, MPC11, LC4800, LC9600, and MX304. This issue affects Junos OS: * all versions before 21.2R3-S9, * from 21.4 before 21.4R3-S10, * from 22.2 before 22.2R3-S7, * from 22.3 before 22.3R3-S4, * from 22.4 before 22.4R3-S5, * from 23.2 before 23.2R2-S3, * from 23.4 before 23.4R2-S3, * from 24.2 before 24.2R1-S2, 24.2R2.
An Improper Check for Unusual or Exceptional Conditions vulnerability in the routing protocol daemon (rpd) of Juniper Networks Junos OS and Junos OS Evolved allows an unauthenticated, network-based attacker to cause an availability impact for downstream devices. When an affected device receives a specific optional, transitive BGP attribute over an existing BGP session, it will be erroneously modified before propagation to peers. When the attribute is detected as malformed by the peers, these peers will most likely terminate the BGP sessions with the affected devices and thereby cause an availability impact due to the resulting routing churn. This issue affects: Junos OS: * all versions before 22.4R3-S8, * 23.2 versions before 23.2R2-S5 * 23.4 versions before 23.4R2-S6, * 24.2 versions before 24.2R2-S2, * 24.4 versions before 24.4R2; Junos OS Evolved: * all versions before 22.4R3-S8-EVO, * 23.2 versions before 23.2R2-S5-EVO, * 23.4 versions before 23.4R2-S6-EVO, * 24.2 versions before 24.2R2-S2-EVO, * 24.4 versions before 24.4R2-EVO.
A NULL Pointer Dereference vulnerability in the chassis daemon (chassisd) of Juniper Networks Junos OS on MX, SRX and EX Series allows a local attacker with low privileges to cause a Denial-of-Service (DoS). When a user executes the 'show chassis' command with specifically crafted options, chassisd will crash and restart. Due to this all components but the Routing Engine (RE) in the chassis are reinitialized, which leads to a complete service outage, which the system automatically recovers from. This issue affects: Junos OS on MX, SRX and EX Series, except MX10000 Series and MX304: * all versions before 22.4R3-S8, * 23.2 versions before 23.2R2-S5, * 23.4 versions before 23.4R2-S6, * 24.2 versions before 24.2R2-S2, * 24.4 versions before 24.4R2.
An Untrusted Pointer Dereference vulnerability in the routing protocol daemon (rpd) of Juniper Networks Junos OS and Junos OS Evolved allows a local, authenticated attacker with low privileges to cause a Denial-of-Service (DoS). When the command 'show route < ( receive-protocol | advertising-protocol ) bgp > detail' is executed, and at least one of the routes in the intended output has specific attributes, this will cause an rpd crash and restart. 'show route ... extensive' is not affected. This issue affects: Junos OS: * all versions before 22.4R3-S8, * 23.2 versions before 23.2R2-S5, * 23.4 versions before 23.4R2-S5, * 24.2 versions before 24.2R2-S2, * 24.4 versions before 24.4R2; Junos OS Evolved: * all versions before 22.4R3-S8-EVO, * 23.2 versions before 23.2R2-S5-EVO, * 23.4 versions before 23.4R2-S6-EVO, * 24.2 versions before 24.2R2-S2-EVO, * 24.4 versions before 24.4R2-EVO.
A clickjacking vulnerability exists in the web portal of Juniper Networks Paragon Automation (Pathfinder, Planner, Insights) due to the application's failure to set appropriate X-Frame-Options and X-Content-Type HTTP headers. This vulnerability allows an attacker to trick users into interacting with the interface under the attacker's control. This issue affects all versions of Paragon Automation (Pathfinder, Planner, Insights) before 24.1.1.