Authenticated Command Injection allows arbitrary command execution in CLI Interface
Summary
A vulnerability in the command line interface of ECOS devices could allow a highly privileged, authenticated remote attacker to perform command injection on certain CLI commands. Successful exploitation could allow an attacker to execute arbitrary commands on the underlying operating system. Affected product named by the advisory: EdgeConnect SD-WAN Gateway (ECOS).
What this means
In plain English
A vulnerability in the command line interface of ECOS devices could allow a highly privileged, authenticated remote attacker to perform command injection on certain CLI commands. Successful exploitation could allow an attacker to execute arbitrary commands on the underlying operating system. Affected product named by the advisory: EdgeConnect SD-WAN Gateway (ECOS). Command injection can cross the boundary between application input and operating-system commands, potentially exposing the underlying host.
Recommended action
Primary action: update to a vendor-listed fixed release: ECOS 9.4.5.0 or above, ECOS 9.5.5.0 or above, ECOS 9.4.7.0 or above, ECOS 9.5.7.0 or above, ECOS 9.7.0.0 or above. Vendor mitigation: Upgrade affected HPE Aruba Networking devices to an applicable fixed release: ECOS 9.4.5.0 or above, ECOS 9.5.5.0 or above, ECOS 9.4.7.0 or above, ECOS 9.5.7.0 or above, ECOS 9.7.0.0 or above. HPE Aruba Networking recommends that customers upgrade their EdgeConnect SD-WAN Gateways to one of the following ECOS software versions to resolve this vulnerability: ECOS 9.4.5.0 and above, ECOS 9.5.5.0 and above. The main Resolution versions (ECOS 9.4.7.0, ECOS 9.5.7.0, ECOS 9.7.0.0 and above) also address this vulnerability. Temporary workaround: To minimize the likelihood of an attacker exploiting this vulnerability, HPE Aruba Networking recommends that management interfaces be restricted to a dedicated…
Rewritten locally from the scraped official advisory data above; no generative API is used. The vendor advisory is authoritative.
- ECOS 9.4.0.0 through 9.4.4.0
- ECOS 9.5.0.0 through 9.5.4.0
Official advisory · high-confidence parse· fetched 2 hours ago·verify at source
- ECOS 9.4.5.0 or above
- ECOS 9.5.5.0 or above
- ECOS 9.4.7.0 or above
- ECOS 9.5.7.0 or above
- ECOS 9.7.0.0 or above
Official advisory · high-confidence parse· fetched 2 hours ago·verify at source
Mitigation checklist
- Upgrade affected HPE Aruba Networking devices to an applicable fixed release: ECOS 9.4.5.0 or above, ECOS 9.5.5.0 or above, ECOS 9.4.7.0 or above, ECOS 9.5.7.0 or above, ECOS 9.7.0.0 or above.
- HPE Aruba Networking recommends that customers upgrade their EdgeConnect SD-WAN Gateways to one of the following ECOS software versions to resolve this vulnerability: ECOS 9.4.5.0 and above, ECOS 9.5.5.0 and above. The main Resolution versions (ECOS 9.4.7.0, ECOS 9.5.7.0, ECOS 9.7.0.0 and above) also address this vulnerability.
- To minimize the likelihood of an attacker exploiting this vulnerability, HPE Aruba Networking recommends that management interfaces be restricted to a dedicated layer 2 segment/VLAN and/or controlled by firewall policies at layer 3 and above, along with accounting controls for tracking and logging user activities and resource usage. You may contact HPE Services - HPE Aruba Networking for assistance if needed. For more information, please visit HPE Networking Support Portal at https://networkingsupport.hpe.com/home. NOTE: HPE Aruba Networking recommends using RADIUS or TACACS for ECOS user authentication and routing management plane traffic through secure SD-WAN tunnels whenever feasible to strengthen the security and integrity of management communications.
Official advisory · high-confidence parse· fetched 2 hours ago·verify at source
Discussion(0)
No comments yet. Share field notes, upgrade gotchas, or questions — verify against the vendor advisory before acting on community advice.
Sign in to join the discussion.