CVE-2024-5642: Python Vulnerability in NetApp Products

This NetApp advisory covers CVE-2024-5642 in Active IQ Unified Manager for Microsoft Windows and NetApp HCI Compute Node (Bootstrap OS).

Open the NetApp advisory

Key facts

Vendor rating
Medium, CVSS 5.3
CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L · base score 6.5, scored by CISA-ADPAttack vector: network. Attack complexity: low. Privileges required: none. User interaction: none. Scope: unchanged. Confidentiality impact: low. Integrity impact: none. Availability impact: low.
Weakness
  • CWE-noinfo Not enough information
EPSS
0.74% chance of exploitation in the next 30 days (55th percentile). FIRST EPSS, .
CISA SSVC
Exploitation: none observed. Automatable: no. Technical impact: partial. CISA, .
CISA KEV
Not listed (catalogue checked )
Fixed in
Active IQ Unified Manager for Microsoft Windows: 9.12, Active IQ Unified Manager for Microsoft Windows: 9.13, Active IQ Unified Manager for Microsoft Windows: 9.14
Advisory id
NTAP-20240726-0005
Source published
Source revised
Listed by VulniPulse

Compiled by VulniPulse from the linked sources. How records are collected and checked.

Affected products & platforms

NetAppElement SoftwareActive IQ Unified Manager

Description

Multiple NetApp products incorporate Python. Python (CPython) versions through 3.9 are susceptible to a vulnerability which when successfully exploited could lead to disclosure of sensitive information.

Successful exploitation of this vulnerability could lead to disclosure of sensitive information. Affected products: Active IQ Unified Manager for Microsoft Windows, NetApp HCI Compute Node (Bootstrap OS).

NetApp reports that one or more additional products remain under investigation; review the canonical advisory for current status. NetApp states there is no workaround available at this time.

Text from the source record.

How to fix CVE-2024-5642

Upgrade to a fixed release named by NetApp:

  • Active IQ Unified Manager for Microsoft Windows: 9.12
  • Active IQ Unified Manager for Microsoft Windows: 9.13
  • Active IQ Unified Manager for Microsoft Windows: 9.14

Vendor guidance

  • Update affected NetApp products to a fixed release: Active IQ Unified Manager for Microsoft Windows: 9.12, Active IQ Unified Manager for Microsoft Windows: 9.13, Active IQ Unified Manager for Microsoft Windows: 9.14.
  • NetApp HCI Compute Node (Bootstrap OS) has no planned fix; migrate to a supported release or product and consult NetApp's end-of-support notice.

NetApp advisories, July 2024All NetApp advisories

Get an email when NetApp SolidFire / Element / HCI publishes the next one.

See NetApp SolidFire / Element / HCI's last 90 days first. Live alerts for one product are free for life; every vendor is US$15 a month after a free month.

Alert me about NetApp SolidFire / Element / HCI