CVE-2024-5642: Python Vulnerability in NetApp Products
This NetApp advisory covers CVE-2024-5642 in Active IQ Unified Manager for Microsoft Windows and NetApp HCI Compute Node (Bootstrap OS).
- CVE-2024-5642
Key facts
- Vendor rating
- Medium, CVSS 5.3
- CVSS vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L· base score 6.5, scored by CISA-ADPAttack vector: network. Attack complexity: low. Privileges required: none. User interaction: none. Scope: unchanged. Confidentiality impact: low. Integrity impact: none. Availability impact: low.- Weakness
- CWE-noinfo Not enough information
- EPSS
- 0.74% chance of exploitation in the next 30 days (55th percentile). FIRST EPSS, .
- CISA SSVC
- Exploitation: none observed. Automatable: no. Technical impact: partial. CISA, .
- CISA KEV
- Not listed (catalogue checked )
- Fixed in
- Active IQ Unified Manager for Microsoft Windows: 9.12, Active IQ Unified Manager for Microsoft Windows: 9.13, Active IQ Unified Manager for Microsoft Windows: 9.14
- Advisory id
- NTAP-20240726-0005
- Source published
- Source revised
- Listed by VulniPulse
Compiled by VulniPulse from the linked sources. How records are collected and checked.
Affected products & platforms
Description
Multiple NetApp products incorporate Python. Python (CPython) versions through 3.9 are susceptible to a vulnerability which when successfully exploited could lead to disclosure of sensitive information.
Successful exploitation of this vulnerability could lead to disclosure of sensitive information. Affected products: Active IQ Unified Manager for Microsoft Windows, NetApp HCI Compute Node (Bootstrap OS).
NetApp reports that one or more additional products remain under investigation; review the canonical advisory for current status. NetApp states there is no workaround available at this time.
Text from the source record.
How to fix CVE-2024-5642
Upgrade to a fixed release named by NetApp:
- Active IQ Unified Manager for Microsoft Windows: 9.12
- Active IQ Unified Manager for Microsoft Windows: 9.13
- Active IQ Unified Manager for Microsoft Windows: 9.14
Vendor guidance
- Update affected NetApp products to a fixed release: Active IQ Unified Manager for Microsoft Windows: 9.12, Active IQ Unified Manager for Microsoft Windows: 9.13, Active IQ Unified Manager for Microsoft Windows: 9.14.
- NetApp HCI Compute Node (Bootstrap OS) has no planned fix; migrate to a supported release or product and consult NetApp's end-of-support notice.
More NetApp advisories
CVE-2025-22233Jul 4, 2025Spring Framework Vulnerability in NetApp ProductsCVE-2026-114583Nov 6, 2026CPython Vulnerability in NetApp ProductsCVE-2026-19445Nov 6, 2026CPython Vulnerability in NetApp ProductsCVE-2026-115557Nov 6, 2026CPython Vulnerability in NetApp ProductsCVE-2026-114820Oct 28, 2026Java SE Vulnerability in NetApp ProductsCVE-2026-22063Oct 27, 2026eMudhra CA Certificate Compromise in NetApp Products
Get an email when NetApp SolidFire / Element / HCI publishes the next one.
See NetApp SolidFire / Element / HCI's last 90 days first. Live alerts for one product are free for life; every vendor is US$15 a month after a free month.